How to access WebUI the first time and change default password

From firmware 0.24.251102 it is required to change the password the first time connection to WebUI is done. If using a firmware older than 0.24.251102 there is no WiFi password.

This procedure is also requested in case of factory reset or firmware update.

Objective

  • Access the WebUI using the default credentials.

  • Change default credentials.


Requirements

  • Zenith55 receiver updated to firmware 0.24.251102.


Procedure

  • Turn on the Zenith55 instrument.

  1. Make sure that the WLAN on your PC/mobile device is turned on. Search for available connections.

  2. When the instrument is found, select it to connect with your PC/mobile device.

    image-20251204-215850.png
  3. Enter the default Zenith55 WiFi password: Geo!20110517

In firmware older than 0.24.251102 there is no password to connect to Zenith55 WiFi.

  1. As soon as the connection is established, start a web browser. Enter the IP http:// 192.168.10.1 into the address bar. A login-window will pop up.

    image-20250604-155055.png
  2. Enter the user name and password. The default values are:

    1. User name: admin

    2. Password: Geo!20110517

In firmware older than 0.24.251102 the login details are admin/password

  1. After connection it is requested to change the default password.

    image-20251204-215917.png
  2. It is required to change the default WiFi password:

    1. WebUI Login Authentication: password to authenticate in WebUI.

    2. WiFi Connect Authentication: password to connect to WiFi network.

  3. Enter the default password and the new password for WebUI Login Authentication. Click Change to confirm.

  4. Enter the default password and the new password for WIFI Connect Authentication. Click Change to confirm.

    image-20251204-215947.png

In some platforms, such as Windows 11, since the WiFi password is changed it is necessary to forget the saved Zenith55 from list of known networks, and search and connect again to Zenith55 WiFi network.

  1. After a successful login, the Position/Link Information screen of the Zenith55 WebManager appears and the instrument can be accessed.

    image-20250604-155150.png