Recording of raw data during survey

X-PAD Ultimate Survey 1.png | X-PAD Ultimate GO 2.png

  • In cases where an own base is unavailable or where it is impossible to connect to a network of permanent stations, record all survey session data in a file with proprietary format RINEX format.

  • Post-process the data in the office to obtain precise coordinates for the base.

This procedure is used to perform a stop&go survey. When the log is started, the raw data is flagged as kinematic. When a point it is measured, a static session is recorded.

For a traditional static survey refer to Static survey of points.


  • In the Survey points page click Tools.

  • Select Start log.

    image-20250708-095612.png
  • The page Log file is opened.

    image-20250708-095741.png
    • Log file: name of the file where the raw data are stored.

    • Occup.time: time of acquisition of single point.

    • Logging rate: frequency of the data recording for post-processing.

    • File type: sets the file’s type to store.

    • Antenna height: sets the height of antenna to store.

  • Click Next to start to log raw data.

  • Kinematic raw data is now recorded, to start a static occupation press Measure to measure a point.

  • Recording of raw data is stops automatically when the survey of points procedure ends or it can be interrupted at any moment pressing Tools and selecting Stop log.