In cases where an own base is unavailable or where it is impossible to connect to a network of permanent stations, record all survey session data in a file with proprietary format RINEX format.
-
Post-process the data in the office to obtain precise coordinates for the base.
This procedure is used to perform a stop&go survey. When the log is started, the raw data is flagged as kinematic. When a point it is measured, a static session is recorded.
For a traditional static survey refer to Static survey of points.
-
In the Survey points page click Tools.
-
Select Start log.
-
The page Log file is opened.
-
Log file: name of the file where the raw data are stored.
-
Occup.time: time of acquisition of single point.
-
Logging rate: frequency of the data recording for post-processing.
-
File type: sets the file’s type to store.
-
Antenna height: sets the height of antenna to store.
-
-
Click Next to start to log raw data.
-
Kinematic raw data is now recorded, to start a static occupation press Measure to measure a point.
-
Recording of raw data is stops automatically when the survey of points procedure ends or it can be interrupted at any moment pressing Tools and selecting Stop log.